User`s manual

SuperH Family E10A-USB Emulator Section 2 Software Specifications when Using the SH7766
R20UT2190EJ0100 Rev.1.00 Page 10 of 34
Aug 09, 2012
A file of I/O-register definitions is stored in the location below.
\(Hew)\Tools\Renesas\DebugComp\Platform\E10A-USB\SH-4A\SH-4\IOFiles
The location of the Hew folder will vary according to where the customer has installed it.
As a default, the folder is installed in the C:\Program Files\Renesas\Hew folder.
Verify
In the [IO] window, the verify function of the input value is disabled.
14. Illegal Instructions
If illegal instructions are executed by STEP-type commands, the emulator cannot go to the
next program counter.
15. [Reset CPU] and [Reset Go] in the [Debug] Menu
In the [Configuration] dialog box, when [Auto] is set as [Reset Mode], the H-UDI reset is
issued at selection of [Reset CPU] or [Reset Go].
For the H-UDI reset, the watchdog timer except for the overflow counter and the clock
oscillator is not initialized.
To initialize all the resources, select [User] from the [Reset Mode] combo box in the
[Configuration] dialog box. At this time, if [Reset CPU] or [Reset Go] is executed, the reset
signal will be waited for being input from the user system.