User`s manual

12
When the circuit is connected as shown in figure 1.6, the switches of the emulator are set as SW2
= 0 and SW3 = 1. For details, refer to section 3.8, Setting the DIP Switches, in the Debugger Part
of the SuperH
TM
Family E10A-USB Emulator User’s Manual.
1
TCK
TMS
RESET
TDI
TDO
TRST
GND
GND
GND
GND
(GND)
2
3
4
5
6
7
9
10
12
13
14
TCK
RES
TMS
TDO
TDI
TRST
SH7047F
59
63
58
61
60
87
ASEBRKAK
ASEBRKAK
11
DBGMD
16
N.C.
N.C.
8
11
H-UDI port connector
(14-pin type)
Reset signal
Pulled-up at 4.7 k
or more (all)
User system
VccQ = 5.0 V (I/O power supply)
FWP
83
Jumper pins
switched
*1
*2
VccQ
Figure 1.6 Circuit for Connection between the H-UDI Port Connector and MCU when the
Emulator is in Use (14-Pin Type UVCC Not Connected
*2
)
Notes: 1. The FWP pin must be 0 (low) by switching jumper pins when the emulator is used.
2. When UVCC is not connected and the user system is turned off, note that the leakage
current flows from the emulator to the user system.