User`s manual

SuperH Family E10A-USB Emulator Section 2 Software Specifications when Using the SH7752
R20UT2163EJ0200 Rev. 2.00 Page 15 of 43
May 23, 2013
9. Port
The AUD pins are multiplexed as shown in table 2.2.
Table 2.2 Multiplexed Functions
Function 1 Function 2
PTL1/RAC-DCD#/DCD0# AUDCK (AUD)
PTL2/RAC-DSR#/DSR0# AUDSYNC (AUD)
PTT7/PWMX7/MD2 AUDATA3 (AUD)
PTT6/PWMX6 AUDATA2 (AUD)
PTT5/PWMX5 AUDATA1 (AUD)
PTT4/PWMX4 AUDATA0 (AUD)
Note: Function 1 can be used when the AUD pins of the device are not connected to the
emulator.
When the AUD trace is enabled, the emulator changes settings so that function 2 is forcibly
used.
10. UBC
When [User] is specified in the [UBC mode] list box in the [Configuration] dialog box, the
UBC can be used in the user program.
Do not use the UBC in the user program as it is used by the emulator when [EML] is specified
in the [UBC mode] list box in the [Configuration] dialog box.
11. Memory Access during Break
In the enabled MMU, when a memory is accessed and a TLB error occurs during break, it can
be selected whether the TLB exception is controlled or the program jumps to the user
exception handler in [TLB Mode] in the [Configuration] dialog box. When [TLB miss
exception is enable] is selected, a “Communication Timeout error” will occur if the TLB
exception handler does not operate correctly. When [TLB miss exception is disable] is
selected, the program does not jump to the TLB exception handler even if a TLB exception
occurs. Therefore, if the TLB exception handler does not operate correctly, a “Communication
Timeout error” will not occur but the memory contents may not be correctly displayed.
12. Loading Sessions
Information in [JTAG clock] of the [Configuration] dialog box cannot be recovered by loading
sessions. Thus the TCK value will be 5 MHz.
If the [Search the best JTAG clock] option is used when the emulator is initiated, the TCK
value will be initialized as a value that has been automatically acquired.