User`s manual

SuperH Family E10A-USB Emulator for Multi-core Microcomputers Section 5 Debugging
R20UT0363EJ0500 Rev. 5.00 Page 95 of 296
Aug 10, 2012
Figure 5.13 [Monitor] Window
During user program execution, the display is updated according to the setting value of the auto-
update interval.
Note: Select [Refresh] from the popup menu when data is not displayed correctly after changing
the address or content of memory.
5.4.2 Changing the Monitor Settings
Selecting [Monitor Settings...] from the popup menu of the [Monitor] window displays the [Monitor
Setting] dialog box, which allows the settings to be changed.
Colors, the size of accesses, and the display format can be easily changed from [Color] or [Access]
of the popup menu.
5.4.3 Temporarily Stopping Update of the Monitor
During user program execution, the display of the [Monitor] window is automatically updated
according to the auto-update interval. Select [Lock Refresh] from the popup menu of the [Monitor]
window to stop the update of display. The characters in the address section are displayed in black,
and the update of display is stopped.
Selecting [Lock Refresh] again from the popup menu cancels the stopped state.
5.4.4 Deleting the Monitor Settings
Selecting [Close] from the popup menu of the [Monitor] window to be deleted closes the [Monitor]
window and deletes the monitor settings.