User`s manual

SuperH Family E10A-USB Emulator for Multi-core Microcomputers Section 5 Debugging
R20UT0363EJ0500 Rev. 5.00 Page 94 of 296
Aug 10, 2012
[Auto-Refresh at rate]: Sets the interval for acquisition by monitoring.
[Reading the Initial Value]: Selects reading of the values in the monitored area when the
monitor window is opened.
[Color]: Sets the method to update monitoring and the attribute of colors.
[Change Indicator]: Selects how to display the values that have changed during
monitoring (available when [Reading the Initial Value] has been
selected).
No change: No color change.
Change: Color is changed according to the [Foreground] and
[Background] options.
Gray: Those data with values that have not been changed are
displayed in gray.
Appear: A value is only displayed after changed.
[Foreground]: Sets the color used for display (available when [Change] has
been selected).
[Background]: Sets the background color (available when [Change] has been
selected).
[Mayfly]: A check in this box selects restoration of the color of those data
which have not been updated in a specified interval to the color
selected in the [Background] option. The specified interval is
the interval for monitor acquisition (available when [Change],
[Gray], or [Appear] has been selected).
[Detail]: Not supported in the emulator.
[History]: Displays the previous settings.
Note: Selection of the foreground or background color may not be available depending on the
operating system in use.
After setting, clicking the [OK] button displays the [Monitor] window.