User`s manual

SuperH Family E10A-USB Emulator Section 3 Preparation before Use
R20UT0870EJ1000 Rev. 10.00 Page 65 of 292
Aug 10, 2012
15. After the following dialog box is displayed, input the ID code as a security code for the flash
memory. However, H’FFFFFFFF is disabled as the ID code.
Input this ID code when [E10A-USB Emulator] is selected and the [New ID code] check box
is unselected on activating the emulator. If the ID code is not matched or the [New ID code]
check box is selected, the flash memory contents are erased.
Figure 3.48 [ID Code] Dialog Box
16. When "Connected" is displayed in the [Output] window of the High-performance Embedded
Workshop, the emulator initiation is completed.
Figure 3.49 [Output] Window
Note: When the user program has already been downloaded to the flash memory, source-level
debugging cannot be executed because there is no debugging information on the user
program after the emulator has been activated. Be sure to load the debugging information
file. For details, refer to section 4.2.1, Setting at Emulator Activation.