User`s manual

SuperH Family E10A-USB Emulator Section 6 Tutorial
R20UT0870EJ1000 Rev. 10.00 Page 247 of 292
Aug 10, 2012
6.21.2 Profiling Function
The profiling function can measure performance for each function.
Notes: 1. Realtime operation is not possible while this function is in operation, since internal
breaks are generated during program execution. Measuring the profile itself affects the
measurements.
2. Performance profile measurement is not supported for all products. On those products
for which it is supported, its characteristics differ according to the product. For details
on the specifications of each product, refer to the additional document, Supplementary
Information on Using the SHxxxx.
3. This function cannot be used with the performance measurement function that has
been described before. Use one of these functions.
First, download the tutorial program by referring to section 6.6, Downloading the Tutorial
Program.
Select [Profile] from the [Performance] submenu of the [View] menu. The [Profile] window
will be displayed.
Figure 6.56 [Profile] Window
To enable the profiling function, place the mouse cursor on an entry in the [List] sheet of the
[Profile] window, click the right-hand mouse button, and then select [Enable Profiler] from the
popup menu.