User`s manual

SuperH Family E10A-USB Emulator Section 5 Debugging
R20UT0870EJ1000 Rev. 10.00 Page 180 of 292
Aug 10, 2012
Examples
E10A-USB: [Cont0] – [Port1]:
The emulator is connected to port 1 of USB controller 0.
E10A-USB: [Cont4] – [Port7][Port3]:
The emulator is connected to general hub port 3 connected to port 7 of USB controller 4 (only
selectable when a USB hub is connected).
5.10 Start/Stop Function
The start/stop function is useful if you wish to control a user system in synchronization with
starting and stopping of user program execution.
To open the [Start/Stop Function Setting] dialog box, select [Setup -> Emulator -> Start/Stop
function setting…] or click on the [Start/Stop Function Setting dialog box] toolbar button.
Figure 5.51 [Start/Stop Function Setting dialog box] Toolbar Button
Figure 5.52 [Start/Stop Function Setting] Dialog Box