User`s manual

SuperH Family E10A-USB Emulator Section 5 Debugging
R20UT0870EJ1000 Rev. 10.00 Page 156 of 292
Aug 10, 2012
(3) [Data] page
Set a data condition.
Figure 5.32 [Trace Filter] Dialog Box ([data] Page)
[Don't care]: Detects no data when this box is checked.
[Setting]: Detects the specified data.
[Point]: Specifies single data (not available when [Don’t care] has been checked).
[Range]: Specifies a data range (not available when [Don’t care] has been checked).
[From]: Enter single data or the minimum value of the data range (not available when
[Don’t care] has been checked).
[To]: Enter the maximum value of the data range (only available when [Range] has
been selected).
Note: Along with setting the data range, the minimum and maximum values can be set in the
[From] and [To] options, respectively.