User`s manual

SuperH Family E10A-USB Emulator Section 5 Debugging
R20UT0870EJ1000 Rev. 10.00 Page 138 of 292
Aug 10, 2012
(1) [Trace mode] page
Sets trace acquisition conditions.
Figure 5.20 [Acquisition] Dialog Box ([Trace mode] Page)
This dialog box specifies the methods and conditions for the acquisition of trace information.
[Trace type]: Selects the type of the trace function.
[AUD function] Uses the AUD trace function.
[Internal trace] Uses the internal trace function.
The following can only be set when the AUD trace function is used.
[AUD function]: Sets the trace acquisition condition.
For a description of the conditions for trace acquisition, refer to section 2.2.2, AUD Trace
Function.