User`s manual

SuperH Family E10A-USB Emulator Section 5 Debugging
R20UT0870EJ1000 Rev. 10.00 Page 128 of 292
Aug 10, 2012
5.5.12 [Breakpoint] Dialog Box
Figure 5.15 [Breakpoint] Dialog Box
This dialog box specifies break conditions.
A breakpoint address to be set is specified in the [Value] edit box. The PC register can also be
specified such as #PC. Up to 255 breakpoints can be specified.
The contents to be set differ depending on the product. For details, refer to the on-line help for
each product.
When [Value] is selected, if an overloaded function or class name including a member function is
specified in address, the [Select Function] dialog box opens.
Clicking the [OK] button sets the break conditions. Clicking the [Cancel] button closes this dialog
box without setting the break conditions.