5.3.3 Temporarily Stopping Update of the Monitor
During user program execution, the display of the [Monitor] window is automatically updated
according to the auto-update interval. Select [Lock Refresh] from the popup menu of the
[Monitor] window to stop the update of display. The characters in the address section are
displayed in black, and the update of display is stopped.
Selecting [Lock Refresh] again from the popup menu cancels the stopped state.
5.3.4 Deleting the Monitor Settings
Selecting [Close] from the popup menu of the [Monitor] window to be deleted closes the
[Monitor] window and deletes the monitor settings.
5.3.5 Monitoring Variables
Using the [Watch] window refers to the value of any variables.
When the address of the variable registered in the [Watch] window exists within the monitoring
range that has been set by the Monitor function, the value of the variable can be updated and
displayed.
This function allows checking the content of a variable without affecting the realtime operation.