2.18. Compare Match Timer Driver
The driver functions support the use of the two 16-bit timers, providing the following operations.
1. Configuration for use, including
• Automatic clock setting using frequency or period as an input.
• Manual clock setting using register values as inputs.
• Automatic interrupt control
2. Configuration for use as a one-shot timer.
3. Disabling channels that are no longer required and enabling low-power mode.
4. Control of a timer, including constant register updates, change of frequency.
5. Reading the counter value and status flag.
Note: The Clock Generation Circuit must be configured before configuring any timer channel.
R20UT0084EE0112 Rev.1.12 Page 2-15