User`s manual
RX62N Group, RX621 Group 4. Library Reference
Description (2/2)
[data3]
For n = 0 to 4 or 6 to 10: A pointer to where the TCNT register value shall be stored.
For n = 5 or 11: A pointer to where the TCNTU register value shall be stored.
Specify PDL_NO_PTR if it is not required.
[data4]
For n = 0 to 4 or 6 to 10: A pointer to where the TGRA register value shall be stored.
For n = 5 or 11: A pointer to where the TCNTV register value shall be stored.
Specify PDL_NO_PTR if it is not required.
[data5]
For n = 0 to 4 or 6 to 10: A pointer to where the TGRB register value shall be stored.
For n = 5 or 11: A pointer to where the TCNTW register value shall be stored.
Specify PDL_NO_PTR if it is not required.
[data6]
For n = 0, 3, 4, 6, 9 or 10: A pointer to where the TGRC register value shall be stored.
For n = 5 or 11: A pointer to where the TGRU register value shall be stored.
Specify PDL_NO_PTR if it is not required.
[data7]
For n = 0, 3, 4, 6, 9 or 10: A pointer to where the TGRD register value shall be stored.
For n = 5 or 11: A pointer to where the TGRV register value shall be stored.
Specify PDL_NO_PTR if it is not required.
[data8]
For n = 0 or 6: A pointer to where the TGRE register value shall be stored.
For n = 5 or 11: A pointer to where the TGRW register value shall be stored.
Specify PDL_NO_PTR if it is not required.
[data9]
For n = 0 or 6: A pointer to where the TGRF register value shall be stored.
Specify PDL_NO_PTR if it is not required.
Return value
True if all parameters are valid and exclusive; otherwise false.
Category
Multi-function Timer Pulse Unit
Reference
None.
Remarks
•
If the flags are read, any detection flag that has been set to 1 shall be automatically cleared to 0
by this function.
R20UT0084EE0112 Rev.1.12 Page 4-111
July. 16, 2014