User`s manual
RX62N Group, RX621 Group 4. Library Reference
Description (3/4)
[data4]
The buffer control settings to be modified. All settings are optional.
If multiple selections are required, use "|" to separate each selection.
•
Output level buffer control (applies only to reset-synchronised or complementary PWM modes).
Set the output control to be transferred to the output:
PDL_MTU2_OUT_BUFFER_P_PHASE_1_LOW or
PDL_MTU2_OUT_BUFFER_P_PHASE_1_HIGH
For n = 0: MTIOC3B.
For n = 1: MTIOC9B.
PDL_MTU2_OUT_BUFFER_N_PHASE_1_LOW or
PDL_MTU2_OUT_BUFFER_N_PHASE_1_HIGH
For n = 0: MTIOC3D.
For n = 1: MTIOC9D.
PDL_MTU2_OUT_BUFFER_P_PHASE_2_LOW or
PDL_MTU2_OUT_BUFFER_P_PHASE_2_HIGH
For n = 0: MTIOC4A.
For n = 1: MTIOC10A.
PDL_MTU2_OUT_BUFFER_N_PHASE_2_LOW or
PDL_MTU2_OUT_BUFFER_N_PHASE_2_HIGH
For n = 0: MTIOC4C.
For n = 1: MTIOC10C.
PDL_MTU2_OUT_BUFFER_P_PHASE_3_LOW or
PDL_MTU2_OUT_BUFFER_P_PHASE_3_HIGH
For n = 0: MTIOC4B.
For n = 1: MTIOC10B.
PDL_MTU2_OUT_BUFFER_N_PHASE_3_LOW or
PDL_MTU2_OUT_BUFFER_N_PHASE_3_HIGH
For n = 0: MTIOC4D.
For n = 1: MTIOC10D.
•
Set the transfer timing
In complementary PWM modes:
PDL_MTU2_OUT_BUFFER_TRANSFER_DISABLE or
PDL_MTU2_OUT_BUFFER_TRANSFER_CREST or
PDL_MTU2_OUT_BUFFER_TRANSFER_TROUGH or
PDL_MTU2_OUT_BUFFER_TRANSFER_BOTH
Disable or enable on detection of
crest,
trough or
both
In Reset-synchronised PWM mode:
PDL_MTU2_OUT_BUFFER_TRANSFER_DISABLE or
PDL_MTU2_OUT_BUFFER_TRANSFER_CLEAR
Disable or enable on counter clear.
•
Buffer transfer to temporary transfer control. Applicable for complementary PWM modes.
PDL_MTU2_BUFFER_TRANSFER_DISABLE or
PDL_MTU2_BUFFER_TRANSFER_ENABLE or
PDL_MTU2_BUFFER_TRANSFER_LINK
Disable transfers,
enable without linking to interrupt skipping
or enable and link to interrupt skipping.
[data5]
Brushless DC motor control settings. All settings are optional.
If multiple selections are required, use "|" to separate each selection.
Applies only to reset-synchronised or complementary PWM modes
•
Brushless DC motor waveform control
PDL_MTU2_BDCM_ENABLE or
PDL_MTU2_BDCM_DISABLE
Enable or disable brushless DC motor control
PDL_MTU2_BDCM_P_PHASE_ENABLE or
PDL_MTU2_BDCM_P_PHASE_DISABLE
Enable or disable PWM outputs on the
positive-phase output pins.
PDL_MTU2_BDCM_N_PHASE_ENABLE or
PDL_MTU2_BDCM_N_PHASE_DISABLE
Enable or disable PWM outputs on the
negative-phase output pins.
PDL_MTU2_BDCM_OPS_FB or
Use input capture signals for output switch
control, or
PDL_MTU2_BDCM_OPS_000 or
PDL_MTU2_BDCM_OPS_001 or
PDL_MTU2_BDCM_OPS_010 or
PDL_MTU2_BDCM_OPS_011 or
PDL_MTU2_BDCM_OPS_100 or
PDL_MTU2_BDCM_OPS_101 or
PDL_MTU2_BDCM_OPS_110 or
PDL_MTU2_BDCM_OPS_111
Set the outputs according to table 17.41 in the
hardware manual.
R20UT0084EE0112 Rev.1.12 Page 4-107
July. 16, 2014