RX62N Group, RX621 Group 4. Library Reference
Description (2/4)
[data3]
The output control settings to be modified. All settings are optional.
If multiple selections are required, use "|" to separate each selection.
Output control.
Select one option for each output.
PDL_MTU2_OUT_P_PHASE_1_ENABLE or
PDL_MTU2_OUT_P_PHASE_1_DISABLE
For n = 0: MTIOC3B.
For n = 1: MTIOC9B.
PDL_MTU2_OUT_N_PHASE_1_ENABLE or
PDL_MTU2_OUT_N_PHASE_1_DISABLE
For n = 0: MTIOC3D.
For n = 1: MTIOC9D.
PDL_MTU2_OUT_P_PHASE_2_ENABLE or
PDL_MTU2_OUT_P_PHASE_2_DISABLE
For n = 0: MTIOC4A.
For n = 1: MTIOC10A.
PDL_MTU2_OUT_N_PHASE_2_ENABLE or
PDL_MTU2_OUT_N_PHASE_2_DISABLE
For n = 0: MTIOC4C.
For n = 1: MTIOC10C.
PDL_MTU2_OUT_P_PHASE_3_ENABLE or
PDL_MTU2_OUT_P_PHASE_3_DISABLE
For n = 0: MTIOC4B.
For n = 1: MTIOC10B.
PDL_MTU2_OUT_N_PHASE_3_ENABLE or
PDL_MTU2_OUT_N_PHASE_3_DISABLE
For n = 0: MTIOC4D.
For n = 1: MTIOC10D.
Or all six phase outputs can be controlled together by selecting one of each:
PDL_MTU2_OUT_P_PHASE_ALL_ENABLE or
PDL_MTU2_OUT_P_PHASE_ALL_DISABLE
All P phase outputs.
PDL_MTU2_OUT_N_PHASE_ALL_ENABLE or
PDL_MTU2_OUT_N_PHASE_ALL_DISABLE
All N phase outputs.
Output inversion control (applies only to reset-synchronised or complementary PWM modes).
Each phase output can be configured for
a) initial high level, active low level or
b) initial low level, active high level.
If dead time is not generated, the options for negative phases will be ignored as their outputs will
always be the inversion of the positive phases.
All six phase outputs can be controlled together by selecting one of each:
PDL_MTU2_OUT_P_PHASE_ALL_HIGH_LOW or
PDL_MTU2_OUT_P_PHASE_ALL_LOW_HIGH
Positive-phase outputs.
PDL_MTU2_OUT_N_PHASE_ALL_HIGH_LOW or
PDL_MTU2_OUT_N_PHASE_ALL_LOW_HIGH
Negative-phase outputs.
Or independently by selecting one option for each required output.
PDL_MTU2_OUT_P_PHASE_1_HIGH_LOW or
PDL_MTU2_OUT_P_PHASE_1_LOW_HIGH
For n = 0: MTIOC3B.
For n = 1: MTIOC9B.
PDL_MTU2_OUT_N_PHASE_1_HIGH_LOW or
PDL_MTU2_OUT_N_PHASE_1_LOW_HIGH
For n = 0: MTIOC3D.
For n = 1: MTIOC9D.
PDL_MTU2_OUT_P_PHASE_2_HIGH_LOW or
PDL_MTU2_OUT_P_PHASE_2_LOW_HIGH
For n = 0: MTIOC4A.
For n = 1: MTIOC10A.
PDL_MTU2_OUT_N_PHASE_2_HIGH_LOW or
PDL_MTU2_OUT_N_PHASE_2_LOW_HIGH
For n = 0: MTIOC4C.
For n = 1: MTIOC10C.
PDL_MTU2_OUT_P_PHASE_3_HIGH_LOW or
PDL_MTU2_OUT_P_PHASE_3_LOW_HIGH
For n = 0: MTIOC4B.
For n = 1: MTIOC10B.
PDL_MTU2_OUT_N_PHASE_3_HIGH_LOW or
PDL_MTU2_OUT_N_PHASE_3_LOW_HIGH
For n = 0: MTIOC4D.
For n = 1: MTIOC10D.
Write access control (applies only to reset-synchronised or complementary PWM modes).
PDL_MTU2_OUT_LOCK_ENABLE
Prevent further changes to the phase
output control.
Toggle output control (applies only to reset-synchronised or complementary PWM modes).
PDL_MTU2_OUT_TOGGLE_ENABLE or
PDL_MTU2_OUT_TOGGLE_DISABLE
Enable or disable toggle output
synchronised with the PWM cycle.
R20UT0084EE0112 Rev.1.12 Page 4-106
July. 16, 2014