User`s manual
RX62N Group, RX621 Group 4. Library Reference
Description (7/8)
[data8]
Configure the input capture / compare match control for general registers TGRU, TRGV and
TGRW. Valid for n = 5 or 11.
The default settings are shown in bold. Specify PDL_NO_DATA to use the defaults.
•
Input capture / compare match control for register TGRU.
PDL_MTU2_U_CM or
Compare match.
PDL_MTU2_U_IC_RISING_EDGE or
PDL_MTU2_U_IC_FALLING_EDGE or
PDL_MTU2_U_IC_BOTH_EDGES or
Input capture at MTICnU rising edge.
Input capture at MTICnU falling edge.
Input capture at MTICnU both edges.
PDL_MTU2_U_IC_PWM_LOW_TROUGH or
PDL_MTU2_U_IC_PWM_LOW_CREST or
PDL_MTU2_U_IC_PWM_LOW_BOTH or
Input capture at trough,
crest or
both for low pulse width measurement.
PDL_MTU2_U_IC_PWM_HIGH_TROUGH or
PDL_MTU2_U_IC_PWM_HIGH_CREST or
PDL_MTU2_U_IC_PWM_HIGH_BOTH
Input capture at trough,
crest or
both for high pulse width measurement.
•
Input capture / compare match control for register TGRV.
PDL_MTU2_V_CM or
Compare match.
PDL_MTU2_V_IC_RISING_EDGE or
PDL_MTU2_V_IC_FALLING_EDGE or
PDL_MTU2_V_IC_BOTH_EDGES or
Input capture at MTICnV rising edge.
Input capture at MTICnV falling edge.
Input capture at MTICnV both edges.
PDL_MTU2_V_IC_PWM_LOW_TROUGH or
PDL_MTU2_V_IC_PWM_LOW_CREST or
PDL_MTU2_V_IC_PWM_LOW_BOTH or
Input capture at trough,
crest or
both for low pulse width measurement.
PDL_MTU2_V_IC_PWM_HIGH_TROUGH or
PDL_MTU2_V_IC_PWM_HIGH_CREST or
PDL_MTU2_V_IC_PWM_HIGH_BOTH
Input capture at trough,
crest or
both for high pulse width measurement.
•
Input capture / compare match control for register TGRW.
PDL_MTU2_W_CM or
Compare match.
PDL_MTU2_W_IC_RISING_EDGE or
PDL_MTU2_W_IC_FALLING_EDGE or
PDL_MTU2_W_IC_BOTH_EDGES or
Input capture at MTICnW rising edge.
Input capture at MTICnW falling edge.
Input capture at MTICnW both edges.
PDL_MTU2_W_IC_PWM_LOW_TROUGH or
PDL_MTU2_W_IC_PWM_LOW_CREST or
PDL_MTU2_W_IC_PWM_LOW_BOTH or
Input capture at trough,
crest or
both for low pulse width measurement.
PDL_MTU2_W_IC_PWM_HIGH_TROUGH or
PDL_MTU2_W_IC_PWM_HIGH_CREST or
PDL_MTU2_W_IC_PWM_HIGH_BOTH
Input capture at trough,
crest or
both for high pulse width measurement.
[data9]
For n = 0 to 4 or 6 to 10: The timer counter TCNT value.
For n = 5 or 11: The timer counter TCNTU value.
[data10]
For n = 0 to 4 or 6 to 10: The register TGRA value.
For n = 5 or 11: The timer counter TCNTV value.
[data11]
For n = 0 to 4 or 6 to 10: The register TGRB value.
For n = 5 or 11: The timer counter TCNTW value.
[data12]
For n = 0, 3, 4, 6, 9 or 10: The register TGRC value.
For n = 5 or 11: The register TGRU value.
Ignored for n = 1, 2, 7 or 8.
[data13]
For n = 0, 3, 4, 6, 9 or 10: The register TGRD value.
For n = 5 or 11: The register TGRV value.
Ignored for n = 1, 2, 7 or 8.
R20UT0084EE0112 Rev.1.12 Page 4-98
July. 16, 2014