User`s manual
RX62N Group, RX621 Group 4. Library Reference
Description (4/8)
•
Control ADC triggers. Valid for n = 4 or 10 in complementary PWM mode unless stated
otherwise
PDL_MTU2_ADC_TRIG_A_DOWN_DISABLE or
PDL_MTU2_ADC_TRIG_A_DOWN_ENABLE
Disable or enable ADC trigger TRGnAN
requests during down-count operation.
PDL_MTU2_ADC_TRIG_B_DOWN_DISABLE or
PDL_MTU2_ADC_TRIG_B_DOWN_ENABLE
Disable or enable ADC trigger TRGnBN
requests during down-count operation.
PDL_MTU2_ADC_TRIG_A_UP_DISABLE or
PDL_MTU2_ADC_TRIG_A_UP_ENABLE
Disable or enable ADC trigger TRGnAN
requests during up-count operation.
This option can be selected in other
modes.
PDL_MTU2_ADC_TRIG_B_UP_DISABLE or
PDL_MTU2_ADC_TRIG_B_UP_ENABLE
Disable or enable ADC trigger TRGnBN
requests during up-count operation.
This option can be selected in other
modes.
[data5]
Configure the buffer operation.
If multiple selections are required, use "|" to separate each selection.
The default settings are shown in bold. Specify PDL_NO_DATA to use the defaults.
•
Control the cycle set buffer transfer timing. Valid for n = 4 or 10.
PDL_MTU2_CSB_DISABLE or
PDL_MTU2_CSB_CREST or
PDL_MTU2_CSB_TROUGH or
PDL_MTU2_CSB_BOTH
Select no transfer,
transfer on crest detection,
transfer on trough detection or
transfer on crest and trough detection.
PDL_MTU2_CSB_TROUGH and PDL_MTU2_CSB_BOTH are available only in
complementary PWM mode.
•
Buffer operation
PDL_MTU2_BUFFER_AC_DISABLE or
PDL_MTU2_BUFFER_AC_ENABLE
Disable or enable buffer operation for registers
TGRA and TGRC. Valid for n = 0, 3, 4 ,6 ,9 or 10.
PDL_MTU2_BUFFER_BD_DISABLE or
PDL_MTU2_BUFFER_BD_ENABLE
Disable or enable buffer operation for registers
TGRB and TGRD. Valid for n = 0, 3, 4 ,6 ,9 or 10.
PDL_MTU2_BUFFER_EF_DISABLE or
PDL_MTU2_BUFFER_EF_ENABLE
Disable or enable buffer operation for registers
TGRE and TGRF. Valid for n = 0 or 6.
•
Buffer data transfer
PDL_MTU2_BUFFER_AC_CM_A or
PDL_MTU2_BUFFER_AC_TCNT_CLR
Transfer the data from TGRC to TGRA when a
compare match A occurs or when TCNT is cleared
in each channel. Valid for n = 0, 3, 4, 6, 9 or 10.
PDL_MTU2_BUFFER_BD_CM_B or
PDL_MTU2_BUFFER_BD_TCNT_CLR
Transfer the data from TGRD to TGRB when a
compare match B occurs or when TCNT is cleared
in each channel. Valid for n = 0, 3, 4, 6, 9 or 10.
PDL_MTU2_BUFFER_EF_CM_E or
PDL_MTU2_BUFFER_EF_TCNT_CLR
Transfer the data from TGRF to TGRE when a
compare match E occurs or when TCNT is cleared
in either channel. Valid for n = 0 or 6.
Transfer on TCNT clear is available only in PWM mode 1 or 2.
R20UT0084EE0112 Rev.1.12 Page 4-95
July. 16, 2014