Datasheet

R01DS0031EJ0210 Rev.2.10 Page 92 of 111
Jul 31, 2012
M16C/65 Group 5. Electrical Characteristics
V
CC1
= V
CC2
= 3 V
Timing Requirements
(V
CC1
= V
CC2
= 3 V, V
SS
= 0 V, at T
opr
= -20°C to 85°C/-40°C to 85°C unless otherwise specified)
5.3.2.3 Timer A Input
Figure 5.22 Timer A Input
Table 5.49 Timer A Input (Counter Input in Event Counter Mode)
Symbol Parameter
Standard
Unit
Min. Max.
t
c(TA)
TAiIN input cycle time
150 ns
t
w(TAH)
TAiIN input high pulse width
60 ns
t
w(TAL)
TAiIN input low pulse width
60 ns
Table 5.50 Timer A Input (Gating Input in Timer Mode)
Symbol Parameter
Standard
Unit
Min. Max.
t
c(TA)
TAiIN input cycle time
600 ns
t
w(TAH)
TAiIN input high pulse width
300 ns
t
w(TAL)
TAiIN input low pulse width
300 ns
Table 5.51 Timer A Input (External Trigger Input in One-Shot Timer Mode)
Symbol Parameter
Standard
Unit
Min. Max.
t
c(TA)
TAiIN input cycle time
300 ns
t
w(TAH)
TAiIN input high pulse width
150 ns
t
w(TAL)
TAiIN input low pulse width
150 ns
Table 5.52 Timer A Input (External Trigger Input in Pulse Width Modulation Mode and
Programmable Output Mode)
Symbol Parameter
Standard
Unit
Min. Max.
t
w(TAH)
TAiIN input high pulse width
150 ns
t
w(TAL)
TAiIN input low pulse width
150 ns
TAiIN input
TAiOUT input
t
w(TAH)
t
c(TA)
t
w(TAL)
t
c(UP)
t
w(UPH)
t