Datasheet
R01DS0032EJ0200 Rev.2.00 Page 47 of 88
Feb 07, 2011
M16C/64A Group 5. Electrical Characteristics
5.1.6 Voltage Detector and Power Supply Circuit Electrical Characteristics
Notes:
1. Select the voltage detection level with the VDSEL1 bit in the OFS1 address.
2. Necessary time until the voltage detector operates when setting to 1 again after setting the VC25 bit in the VCR2
register to 0.
3. Time from when passing the V
det0
until when a voltage monitor 0 reset is generated.
Notes:
1. Select the voltage detection level with bits VD1S0 to VD1S3 in the VD1LS register.
2. Necessary time until the voltage detector operates when setting to 1 again after setting the VC26 bit in the VCR2
register to 0.
3. Time from when passing the V
det1
until when a voltage monitor 1 reset is generated.
Table 5.11 Voltage Detector 0 Electrical Characteristics
The measurement condition is V
CC1
= 2.7 to 5.5 V, T
opr
= -20°C to 85°C/-40°C to 85°C, unless otherwise specified.
Symbol Parameter Condition
Standard
Unit
Min. Typ. Max.
V
det0
Voltage detection level Vdet0_0
(1)
When V
CC1
is falling.
1.60 1.90 2.20 V
Voltage detection level Vdet0_2
(1)
When V
CC1
is falling.
2.55 2.85 3.15 V
-
Voltage detector 0 response time
(3)
When V
CC1
falls from 5 V
to (Vdet0_0 - 0.1) V
200
μs
- Voltage detector self power consumption VC25 = 1, V
CC1
= 5.0 V
1.8
μA
t
d(E-A)
Waiting time until voltage detector operation
starts
(2)
100 μs
Table 5.12 Voltage Detector 1 Electrical Characteristics
The measurement condition is V
CC1
= 2.7 to 5.5 V, T
opr
= -20°C to 85°C/-40°C to 85°C, unless otherwise specified.
Symbol Parameter Condition
Standard
Unit
Min. Typ. Max.
V
det1
Voltage detection level Vdet1_6
(1)
When V
CC1
is falling.
2.79 3.09 3.39 V
Voltage detection level Vdet1_B
(1)
When V
CC1
is falling.
3.54 3.84 4.14 V
Voltage detection level Vdet1_F
(1)
When V
CC1
is falling.
3.94 4.44 4.94 V
- Hysteresis width when V
CC1
of voltage detector
1 is rising
0.15 V
-
Voltage detector 1 response time
(3)
When V
CC1
falls from 5 V
to (Vdet1_0 - 0.1) V
200
μs
- Voltage detector self power consumption VC26 = 1, V
CC1
= 5.0 V
1.8
μA
t
d(E-A)
Waiting time until voltage detector operation
starts
(2)
100 μs