Datasheet
RL78/L12 
  CHAPTER 31 ELECTRICAL SPECIFICATIONS (G: TA = -40 to +105°C) 
R01UH0330EJ0200 Rev.2.00      920 
Dec 13, 2013 
(TA = −40 to +105°C, 2.4 V ≤ EVDD = VDD ≤ 5.5 V, VSS = EVSS = 0 V)  (2/5) 
Items Symbol  Conditions  MIN. TYP. MAX. Unit 
Output current, 
low
Note 1
I
OL1  Per pin for P10 to P17, P30 to P32, P40 to P43, P50 to P54,
P70 to P74, P120, P125 to P127, P130, P140 to P147 
 8.5
 Note 2
mA 
Per pin for P60, P61      15.0
 Note 2
mA 
Total of P10 to P14, P40 to P43, P120,
P130, P140 to P147 
(When duty = 70%
 Note 3
) 
4.0 V ≤ EV
DD ≤ 5.5 V      40.0  mA 
2.7 V ≤ EVDD < 4.0 V      15.0  mA 
2.4 V ≤ EVDD < 2.7 V      9.0  mA 
Total of P15 to P17, P30 to P32, P50 
to P54, P60, P61, P70 to P74, 
P125 to P127 
(When duty = 70%
 Note 3
) 
4.0 V ≤ EV
DD ≤ 5.5 V      40.0  mA 
2.7 V ≤ EVDD < 4.0 V      35.0  mA 
2,4 V ≤ EVDD < 2.7 V      20.0  mA 
Total of all pins 
(When duty = 70%
 Note 3
) 
 80.0 mA 
IOL2  P20, P21  Per pin      0.4  mA 
Total of all pins  2.4 V ≤ VDD ≤ 5.5 V      0.8  mA 
Notes 1.  Value of current at which the device operation is guaranteed even if the current flows from the V
DD and 
EV
DD pins to an output pin. 
  2.  Do not exceed the total current value. 
 3.  Specification under conditions where the duty factor ≤ 70%. 
    The output current value that has changed to the duty factor > 70% the duty ratio can be calculated with the 
following expression (when changing the duty factor from 70% to n%). 
 • Total output current of pins = (I
OL × 0.7)/(n × 0.01) 
    <Example> Where n = 80% and I
OL = 40.0 mA 
      Total output current of pins = (40.0 × 0.7)/(80 × 0.01) ≅ 35.0 mA 
    However, the current that is allowed to flow into one pin does not vary depending on the duty factor. A 
current higher than the absolute maximum rating must not flow into one pin. 
Remark  Unless specified otherwise, the characteristics of alternate-function pins are the same as those of the port 
pins. 