Datasheet
RL78/L12  CHAPTER 30 ELECTRICAL SPECIFICATIONS (A, G: T
A = -40 to +85°C) 
R01UH0330EJ0200 Rev.2.00      905 
Dec 13, 2013 
LVD Detection Voltage of Interrupt & Reset Mode 
(T
A = −40 to +85°C, VPDR ≤ EVDD = VDD ≤ 5.5 V, VSS = EVSS = 0 V) 
Parameter Symbol  Conditions  MIN. TYP. MAX. Unit 
Interrupt and reset 
mode 
V
LVDA0 VPOC2, VPOC1, VPOC0 = 0, 0, 0, falling reset voltage 
1.60 1.63 1.66  V 
VLVDA1    LVIS1, LVIS0 = 1, 0 Rising release reset voltage
1.74 1.77 1.81  V 
Falling interrupt voltage 
1.70 1.73 1.77  V 
VLVDA2  LVIS1, LVIS0 = 0, 1 Rising release reset voltage
1.84 1.88 1.91  V 
Falling interrupt voltage 
1.80 1.84 1.87  V 
VLVDA3  LVIS1, LVIS0 = 0, 0 Rising release reset voltage
2.86 2.92 2.97  V 
Falling interrupt voltage 
2.80 2.86 2.91  V 
VLVDB1 VPOC2, VPOC1, VPOC0 = 0, 0, 1, falling reset voltage 
1.80 1.84 1.87  V 
VLVDB2    LVIS1, LVIS0 = 1, 0 Rising release reset voltage
1.94 1.98 2.02  V 
Falling interrupt voltage 
1.90 1.94 1.98  V 
VLVDB3  LVIS1, LVIS0 = 0, 1 Rising release reset voltage
2.05 2.09 2.13  V 
Falling interrupt voltage 
2.00 2.04 2.08  V 
VLVDB4  LVIS1, LVIS0 = 0, 0 Rising release reset voltage
3.07 3.13 3.19  V 
Falling interrupt voltage 
3.00 3.06 3.12  V 
VLVDC0 VPOC2, VPOC1, VPOC0 = 0, 1, 0, falling reset voltage 
2.40 2.45 2.50  V 
VLVDC1    LVIS1, LVIS0 = 1, 0 Rising release reset voltage
2.56 2.61 2.66  V 
Falling interrupt voltage 
2.50 2.55 2.60  V 
VLVDC2  LVIS1, LVIS0 = 0, 1 Rising release reset voltage
2.66 2.71 2.76  V 
Falling interrupt voltage 
2.60 2.65 2.70  V 
VLVDC3  LVIS1, LVIS0 = 0, 0 Rising release reset voltage
3.68 3.75 3.82  V 
Falling interrupt voltage 
3.60 3.67 3.74  V 
VLVDD0 VPOC2, VPOC1, VPOC0 = 0, 1, 1, falling reset voltage 
2.70 2.75 2.81  V 
VLVDD1    LVIS1, LVIS0 = 1, 0 Rising release reset voltage
2.86 2.92 2.97  V 
Falling interrupt voltage 
2.80 2.86 2.91  V 
VLVDD2  LVIS1, LVIS0 = 0, 1 Rising release reset voltage
2.96 3.02 3.08  V 
Falling interrupt voltage 
2.90 2.96 3.02  V 
VLVDD3  LVIS1, LVIS0 = 0, 0 Rising release reset voltage
3.98 4.06 4.14  V 
Falling interrupt voltage 
3.90 3.98 4.06  V 
30.6.5 Supply voltage rise time 
(T
A = −40 to +85°C, VSS = 0 V) 
Parameter Symbol  Conditions  MIN. TYP. MAX. Unit 
Power supply voltage rising slope  SVDD      54  V/ms
Caution  Make sure to keep the internal reset state by the LVD circuit or an external reset until VDD reaches the 
operating voltage range shown in 30.4 AC Characteristics. 
<R> 
<R> 
<R> 