Datasheet
RL78/L12    CHAPTER 19 STANDBY FUNCTION 
R01UH0330EJ0200 Rev.2.00      743 
Dec 13, 2013 
19.3.3 SNOOZE mode 
(1)  SNOOZE mode setting and operating statuses 
The SNOOZE mode can only be specified for CSI00, UART0, or the A/D converter. Note that this mode can only be 
specified if the CPU clock is the high-speed on-chip oscillator clock. 
When using CSI00 or UART0 in the SNOOZE mode, set the SWCm bit of the serial standby control register m 
(SSCm) to 1 immediately before switching to the STOP mode. For details, see 12.3 Registers Controlling Serial 
Array Unit. 
When using the A/D converter in the SNOOZE mode, set the AWC bit of the A/D converter mode register 2 (ADM2) to 
1 immediately before switching to the STOP mode. For details, see 11.3 Registers Used in A/D Converter. 
In SNOOZE mode transition, wait status to be only following time. 
Transition time from STOP mode to SNOOZE mode: 18 
μ 
s to 65 
μ 
s 
Remark  Transition time from STOP mode to SNOOZE mode varies depending on the temperature conditions and the 
STOP mode period. 
From SNOOZE to normal operation 
• When vectored interrupt servicing is carried out: 
HS (High-speed main) mode :  4.99 to 9.44 
μ 
s + 7 clocks 
LS (Low-speed main) mode :  1.10 to 5.08 
μ 
s + 7 clocks 
LV (Low-voltage main) mode :  16.58 to 25.40 
μ 
s + 7 clocks 
• When vectored interrupt servicing is not carried out: 
HS (High-speed main) mode :  4.99 to 9.44 
μ 
s + 1 clock 
LS (Low-speed main) mode :  1.10 to 5.08 
μ 
s + 1 clock 
LV (Low-voltage main) mode :  16.58 to 25.40 
μ 
s + 1 clock 
The operating statuses in the SNOOZE mode are shown below. 
<R> 
<R> 
<R> 