12.5.9 Procedure for processing errors that occurred during 3-wire serial I/O (CSI00, CSI01) communication 
The procedure for processing errors that occurred during 3-wire serial I/O (CSI00, CSI01) communication is described 
in Figure 12-73. 
Figure 12-73. Processing Procedure in Case of Overrun Error 
Software Manipulation  Hardware Status  Remark 
Reads serial data register mn (SDRmn).  The BFFmn bit of the SSRmn register is 
set to 0 and channel n is enabled to 
receive data. 
This is to prevent an overrun error if the 
next reception is completed during error 
processing. 
Reads serial status register mn 
(SSRmn). 
  Error type is identified and the read 
value is used to clear error flag. 
Writes 1 to serial flag clear trigger 
register mn (SIRmn). 
Error flag is cleared.  Error can be cleared only during 
reading, by writing the value read from 
the SSRmn register to the SIRmn 
register without modification. 
Remark  m: Unit number (m = 0), n: Channel number (n = 0, 1), mn = 00, 01 