Datasheet
RL78/L12    CHAPTER 11 A/D CONVERTER 
R01UH0330EJ0200 Rev.2.00      361 
Dec 13, 2013 
11.6.2 Software trigger mode (one-shot conversion mode) 
<1>  In the stop status, the ADCE bit of A/D converter mode register 0 (ADM0) is set to 1, and the system enters the 
A/D conversion standby status. 
<2>  After the software counts up to the stabilization wait time (1.0 
μ
 s), the ADCS bit of the ADM0 register is set to 1 
to perform the A/D conversion of the analog input specified by the analog input channel specification register 
(ADS). 
<3>  When A/D conversion ends, the conversion result is stored in the A/D conversion result register (ADCR, ADCRH), 
and the A/D conversion end interrupt request signal (INTAD) is generated. 
<4>  After A/D conversion ends, the ADCS bit is automatically cleared to 0, and the system enters the A/D conversion 
standby status. 
<5>  When ADCS is overwritten with 1 during conversion operation, the current A/D conversion is interrupted, and 
conversion restarts. The partially converted data is discarded. 
<6> When the value of the ADS register is rewritten or overwritten during conversion operation, the current A/D 
conversion is interrupted, and A/D conversion is performed on the analog input respecified by the ADS register.  
The partially converted data is discarded. 
<7> When ADCS is cleared to 0 during conversion operation, the current A/D conversion is interrupted, and the 
system enters the A/D conversion standby status. 
<8>  When ADCE is cleared to 0 while in the A/D conversion standby status, the A/D converter enters the stop status. 
When ADCE = 0, specifying 1 for ADCS is ignored and A/D conversion does not start. In addition, A/D 
conversion does not start even if a hardware trigger is input while in the A/D conversion standby status. 
Figure 11-18. Example of Software Trigger Mode (One-Shot Conversion Mode) Operation Timing 
ADCE
ADCS
ADS
INTAD
ADCR,
ADCRH
A/D
conversion
status
ADCE is set to 1.
<1>
ADCS is set to 
1 while in the 
conversion 
standby status.
ADCS is 
automatically 
cleared to 
0 after 
conversion 
ends.
<2> <4> <2> <2>
<4>
<2><4>
A/D
conversion
ends.
<3>
ADCS is overwritten 
with 1 during A/D 
conversion operation.
<5>
Conversion is 
interrupted 
and restarts.
Conversion is
interrupted.
<3>
ADS is rewritten during 
A/D conversion operation 
(from ANI0 to ANI1).
<6>
<3>
ADCE is cleared to 0.
<8>
ADCS is 
cleared to
0 during A/D 
conversion 
operation.
<7>
The trigger
is not
acknowledged.
The trigger
is not
acknowledged.
Conversion
standby
Conversion
standby
Conversion
standby
Conversion
standby
Conversion
standby
Data 0
(ANI0)
Data 1
(ANI1)
Data 0
(ANI0)
Data 0
(ANI0)
Data 0
(ANI0)
Data 0
(ANI0)
Data 1
(ANI1)
Data 0
(ANI0)
Data 0
(ANI0)
Data 1
(ANI1)
Data 1
(ANI1)
Stop
status
Stop
status