Datasheet
RL78/L12    CHAPTER 6 TIMER ARRAY UNIT 
R01UH0330EJ0200 Rev.2.00      272 
Dec 13, 2013 
Figure 6-78. Operation Procedure When PWM Function Is Used (2/2) 
 Software Operation  Hardware Status 
Operation 
start 
Sets the TOEmp bit (slave) to 1 (only when operation is 
resumed). 
The TSmn (master) and TSmp (slave) bits of timer 
channel start register m (TSm) are set to 1 at the same 
time. 
The TSmn and TSmp bits automatically return to 0 
because they are trigger bits. 
TEmn = 1, TEmp = 1 
When the master channel starts counting, INTTMmn is 
generated. Triggered by this interrupt, the slave 
channel also starts counting. 
During 
operation 
Set values of the TMRmn and TMRmp registers, 
TOMmn, TOMmp, TOLmn, and TOLmp bits cannot be 
changed. 
Set values of the TDRmn and TDRmp registers can be 
changed after INTTMmn of the master channel is 
generated. 
The TCRmn and TCRmp registers can always be read. 
The TSRmn and TSRmp registers are not used. 
The counter of the master channel loads the TDRmn 
register value to timer count register mn (TCRmn), and 
counts down. When the count value reaches TCRmn = 
0000H, INTTMmn output is generated. At the same time, 
the value of the TDRmn register is loaded to the TCRmn 
register, and the counter starts counting down again. 
At the slave channel, the value of the TDRmp register is 
loaded to the TCRmp register, triggered by INTTMmn of 
the master channel, and the counter starts counting down. 
The output level of TOmp becomes active one count clock 
after generation of the INTTMmn output from the master 
channel. It becomes inactive when TCRmp = 0000H, and 
the counting operation is stopped. 
After that, the above operation is repeated. 
Operation 
stop 
The TTmn (master) and TTmp (slave) bits are set to 1 at 
the same time. 
The TTmn and TTmp bits automatically return to 0 
because they are trigger bits. 
TEmn, TEmp = 0, and count operation stops. 
The TCRmn and TCRmp registers hold count value and 
stop. 
The TOmp output is not initialized but holds current 
status. 
The TOEmp bit of slave channel is cleared to 0 and value 
is set to the TOmp bit. 
The TOmp pin outputs the TOmp set level. 
TAU 
stop 
To hold the TOmp pin output level 
Clears the TOmp bit to 0 after the value to 
be held is set to the port register. 
When holding the TOmp pin output level is not 
necessary 
  Setting not required. 
The TOmp pin output level is held by port function. 
The TAU0EN bit of the PER0 register is cleared to 0. 
Power-off status 
All circuits are initialized and SFR of each channel is 
also initialized. 
(The TOmp bit is cleared to 0 and the TOmp pin is set 
to port mode.) 
Remark  m: Unit number (m = 0), n: Channel number (n = 0, 2, 4, 6) 
  p: Slave channel number (n < p ≤ 7) 
Operation is resumed. 