Datasheet
RL78/L12  CHAPTER 15 MULTIPLIER AND DIVIDER/MULTIPLY-ACCUMULATOR 
R01UH0330EJ0200 Rev.2.00      672 
Dec 13, 2013 
15.4.3 Multiply-accumulation (unsigned) operation 
• Initial setting 
<1>  Set the multiplication/division control register (MDUC) to 40H. 
<2>  Set the initial accumulated value of higher 16 bits to multiplication/division data register C (L) (MDCL). 
<3>  Set the initial accumulated value of lower 16 bits to multiplication/division data register C (H) (MDCH). 
<4>  Set the multiplicand to multiplication/division data register A (L) (MDAL). 
<5>  Set the multiplier to multiplication/division data register A (H) (MDAH). 
  (There is no preference in the order of executing steps <2>, <3>, and <4>. Multiplication operation is 
automatically started when the multiplier is set to the MDAH register, respectively.) 
•  During operation processing 
<6> The multiplication operation finishes in one clock cycle. 
(The multiplication result is stored in multiplication/division data register B (L) (MDBL) and multiplication/division 
data register B (H) (MDBH).) 
<7>  After <6>, the multiply-accumulation operation finishes in one additional clock cycle. (There is a wait of at least 
two clock cycles after specifying the initial settings is finished (<5>).) 
• Operation end 
<8>  Read the accumulated value (lower 16 bits) from the MDCL register. 
<9>  Read the accumulated value (higher 16 bits) from the MDCH register. 
(There is no preference in the order of executing steps <8> and <9>.) 
(<10> If the result of the multiply-accumulation operation causes an overflow, the MACOF bit is set to 1, INTMD 
signal is occurred.) 
• Next operation 
<11> The next time multiplication, division, or multiply-accumulation is performed, start with the initial settings of each 
step. 
Remark  Steps <1> to <10> correspond to <1> to <10> in Figure 15-8. 