Datasheet
RL78/L12  CHAPTER 15 MULTIPLIER AND DIVIDER/MULTIPLY-ACCUMULATOR 
R01UH0330EJ0200 Rev.2.00      670 
Dec 13, 2013 
15.4 Operations of Multiplier and Divider/Multiply-Accumulator 
15.4.1 Multiplication (unsigned) operation 
• Initial setting 
<1>  Set the multiplication/division control register (MDUC) to 00H. 
<2>  Set the multiplicand to multiplication/division data register A (L) (MDAL). 
<3>  Set the multiplier to multiplication/division data register A (H) (MDAH). 
  (There is no preference in the order of executing steps <2> and <3>. Multiplication operation is automatically 
started when the multiplier and multiplicand are set to the MDAH and MDAL registers, respectively.) 
•  During operation processing 
<4>  Wait for at least one clock. The operation will end when one clock has been issued. 
• Operation end 
<5>  Read the product (lower 16 bits) from multiplication/division data register B (L) (MDBL). 
<6>  Read the product (higher 16 bits) from multiplication/division data register B (H) (MDBH). 
(There is no preference in the order of executing steps <5> and <6>.) 
• Next operation 
<7>  The next time multiplication, division, or multiply-accumulation is performed, start with the initial settings of each 
step. 
Remark  Steps <1> to <7> correspond to <1> to <7> in Figure 15-6. 
Figure 15-6. Timing Diagram of Multiplication (Unsigned) Operation (2 × 3 = 6) 
MDAL 0002H
0003H
0000H
0006H
FFFFH
FFFFH
FFFEH
0001H
0002H
FFFDH
<2>
<1>
<3> <5>, <6>
<4>
00H
MDAH
MDBH
MDBL
MDUC
MDSM
L
<7>
0000H
0000H
0000H
0000H
Operation clock