Datasheet
RL78/L12    CHAPTER 12 SERIAL ARRAY UNIT 
R01UH0330EJ0200 Rev.2.00      454 
Dec 13, 2013 
Figure 12-58. Procedure for Resuming Slave Reception 
Starting setting for resumption
Port manipulation 
Changing setting of the SPSm register
Changing setting of the SMRmn register
Port manipulation 
Writing to the SSm register
Disable clock output of the target 
channel by setting a port register and a 
port mode register. 
Re-set the register to change the 
operation clock setting. 
Re-set the register to change serial mode 
register mn (SMRmn) setting. 
Enable clock output of the target channel 
by setting a port register and a port mode 
register. 
Set the SSmn bit of the target channel to 1 
(SEmn bit = 1: to enable operation).    Wait 
for a clock from the master. 
(Essential) 
(Selective) 
(Selective) 
(Essential) 
(Essential) 
Re-set the register to change serial 
communication operation setting register 
mn (SCRmn) setting. 
(Selective) 
Changing setting of the SCRmn register
If the OVF flag remain set, clear this 
using serial flag clear trigger register mn 
(SIRmn). 
(Selective) 
Clearing error flag 
Completing resumption setting
(Essential) 
Yes 
No 
Wait until stop the communication target 
(master) 
Completing master 
p
re
p
arations? 
Remark If PER0 is rewritten while stopping the master transmission and the clock supply is stopped, wait 
until the transmission target (master) stops or transmission finishes, and then perform initialization 