Datasheet

RL78/L12 CHAPTER 22 VOLTAGE DETECTOR
R01UH0330EJ0200 Rev.2.00 769
Dec 13, 2013
22.4.3 When used as interrupt and reset mode
When starting operation
Specify the operation mode (the interrupt and reset (LVIMDS1, LVIMDS0 = 1, 0)) and the detection voltage
(V
LVDH, VLVDL) by using the option byte 000C1H.
Start in the following initial setting state.
Set bit 7 (LVISEN) of the voltage detection register (LVIM) to 0 (disable rewriting of voltage detection level
register (LVIS)).
When the option byte LVIMDS1 is set to 1 and LVIMDS0 is cleared to 0, the initial value of the LVIS register is
set to 00H.
Bit 7 (LVIMD) is 0 (interrupt mode).
Bit 0 (LVILV) is 0 (low-voltage detection level: V
LVDH).
Figure 22-6 shows the timing of the internal reset signal and interrupt signal generated by the voltage detector.
Perform the processing according to Figure 22-7 Processing Procedure After an Interrupt is Generated.