RL78/L12 CHAPTER 22 VOLTAGE DETECTOR
R01UH0330EJ0200 Rev.2.00 767
Dec 13, 2013
22.4.2 When used as interrupt mode
Specify the operation mode (the interrupt mode (LVIMDS1, LVIMDS0 = 0, 1)) and the detection voltage (V
LVD) by using
the option byte 000C1H.
The operation is started in the following initial setting state when the interrupt mode is set.
Bit 7 (LVISEN) of the voltage detection register (LVIM) is set to 0 (disable rewriting of voltage detection level
register (LVIS))
The initial value of the voltage detection level select register (LVIS) is set to 01H.
Bit 7 (LVIMD) is 0 (interrupt mode).
Bit 0 (LVILV) is 1 (low-voltage detection level: V
LVD).
Operation in LVD interrupt mode
In the interrupt mode (option byte LVIMDS1, LVIMDS0 = 0, 1), the state of an internal reset by LVD is retained
until the supply voltage (V
DD) exceeds the voltage detection level (VLVD) after power is supplied (after the first
release of the POR). The internal reset is released when the supply voltage (V
DD) exceeds the voltage detection
level (VLVD).
An interrupt request signal by LVD (INTLVD) is generated, when the supply voltage (V
DD) falls below the voltage
detection level (V
LVD) or when the supply voltage (VDD) exceeds the voltage detection level (VLVD) after the
second release of the POR. When the voltage falls, this LSI should be placed in the STOP mode, or placed in
the reset state by controlling the externally input reset signal, before the voltage falls below the operating voltage
range defined in 30.4 or 31.4 AC characteristics. When restarting the operation, make sure that the operation
voltage has returned within the range of operation.
Figure 22-5 shows the timing of the interrupt request signal generated in the LVD interrupt mode.