Datasheet
RL78/L12 CHAPTER 12 SERIAL ARRAY UNIT
R01UH0330EJ0200 Rev.2.00 444
Dec 13, 2013
Figure 12-49. Procedure for Stopping Slave Transmission
Starting setting to stop
Stop setting is completed
Write 1 to the STmn bit of the target channel.
(SEmn = 0 : to operation stop status)
The master transmission is stopped.
Go to the next processing.
Set the SOEmn bit to 0 and stop the output of
the target channel.
Writing the STm register
Changing setting of the SOEm register
TSFmn = 0?
If there is any data being transferred, wait for
their completion.
(If there is an urgent must stop, do not wait)
Yes
No
The levels of the serial clock (CKOmn) and
serial data (SOmn) on the target channel can
be changed if necessitated by an emergency.
To use the STOP mode, reset the serial array
unit by stopping the clock supply to it.
Changing setting of the SOm register
Setting the PER0 register
(Essential)
(Selective)
(Essential)
(Selective)
(Selective)