Datasheet

RL78/L12 CHAPTER 6 TIMER ARRAY UNIT
R01UH0330EJ0200 Rev.2.00 175
Dec 13, 2013
(3) Multiple PWM (Pulse Width Modulation) output
By extending the PWM function and using one master channel and two or more slave channels, up to seven types
of PWM signals that have a specific period and a specified duty factor can be generated.
Duty
Period
Interrupt signal (INTTMmn)
Duty
Period
Channel n (master)
Channel p (slave)
Channel q (slave)
Operation clock
Compare operation
Compare operation
Compare operation
Timer output
(TOmp)
Timer output
(TOmq)
(4) Remote control output function
The pairings of channels 2 and 3 and channels 6 and 7 are used to output the PWM signal. The PWM signal
output from channel 3 is used as a mask waves, the PWM signal output from channel 7 is used as a carrier waves,
and the logical products of these signals are output as remote control output.
Operation clock
Compare operation
Compare operation
Channel 2 (master)
Channel 3 (slave)
PWM output (TO03)
(Mask waves)
Remote control output
TO03
PWM output (TO07)
(Carrier waves)
Interrupt signal
(INTTM02)
Operation clock
Compare operation
Compare operation
Channel 6 (master)
Channel 7 (slave)
Latch
Interrupt signal
(INTTM06)
Caution For details about the rules of simultaneous channel operation function, see 6.4.1 Basic rules of
simultaneous channel operation function.
Remark m: Unit number (m = 0), n: Channel number (n = 0 to 7),
p, q: Slave channel number (n < p < q 7)