CHAPTER 31 ELECTRICAL SPECIFICATIONS (G: TA = -40 to +105°C)
R01UH0330EJ0200 Rev.2.00 929
Dec 13, 2013
Notes 1. Current flowing to VDD.
2. When high speed on-chip oscillator and high-speed system clock are stopped.
3. Current flowing only to the real-time clock (RTC) (excluding the operating current of the low-speed on-chip
oscillator and the XT1 oscillator). The supply current of the RL78 microcontrollers is the sum of the values of
either I
DD1 or IDD2, and IRTC, when the real-time clock operates in operation mode or HALT mode. When the
low-speed on-chip oscillator is selected, I
FIL should be added. IDD2 subsystem clock operation includes the
operational current of the real-time clock.
4. Current flowing only to the 12-bit interval timer (excluding the operating current of the low-speed on-chip
oscillator and the XT1 oscillator). The supply current of the RL78 microcontrollers is the sum of the values of
either I
DD1 or IDD2, and IIT, when the 12-bit interval timer operates in operation mode or HALT mode. When the
low-speed on-chip oscillator is selected, IFIL should be added.
5. Current flowing only to the watchdog timer (including the operating current of the low-speed on-chip oscillator).
The supply current of the RL78 microcontrollers is the sum of I
DD1, IDD2 or IDD3 and IWDT when the watchdog
timer is in operation.
6. Current flowing only to the A/D converter. The supply current of the RL78 microcontrollers is the sum of I
DD1 or
I
DD2 and IADC when the A/D converter operates in an operation mode or the HALT mode.
7. Current flowing only to the LVD circuit. The supply current of the RL78 microcontrollers is the sum of IDD1, IDD2
or I
DD3 and ILVD when the LVD circuit is in operation.
8. Current flowing only during data flash rewrite.
9. Current flowing only during self programming.
10. For shift time to the SNOOZE mode, see 19.3.3 SNOOZE mode.
11. Current flowing only to the LCD controller/driver. The supply current value of the RL78 microcontrollers is the
sum of the LCD operating current (I
LCD1, ILCD2 or ILCD3) to the supply current (IDD1 or IDD2) when the LCD
controller/driver operates in an operation mode or HALT mode. Not including the current that flows through the
LCD panel.
The TYP. value and MAX. value are following conditions.
• When fSUB is selected for system clock, LCD clock = 128 Hz (LCDC0 = 07H)
• 4-Time-Slice, 1/3 Bias Method
12. Not including the current that flows through the external divider resistor when the external resistance division
method is used.
Remarks 1. f
IL: Low-speed on-chip oscillator clock frequency
2. fSUB: Subsystem clock frequency (XT1 clock oscillation frequency)
3. f
CLK: CPU/peripheral hardware clock frequency
4. Temperature condition of the TYP. value is T
A = 25°C