(3) Processing flow (in single-reception mode)
Figure 12-35. Timing Chart of Master Reception (in Single-Reception Mode)
(Type 1: DAPmn = 0, CKPmn = 0)
SSmn
SEmn
SDRmn
INTCSIp
TSFmn
STmn
Receive data 1
SCKp pin
SIp pin
Shift
register mn
Data reception Data reception Data reception
Reception & shift operation
Reception & shift operation
Reception & shift operation
Receive data 3Receive data 2
Receive data 1
Dummy data for reception Dummy data
Dummy data
Receive data 2 Receive data 3
Write
Read
Write
Read
Read
Write