RL78/L12 CHAPTER 11 A/D CONVERTER
R01UH0330EJ0200 Rev.2.00 343
Dec 13, 2013
Cautions 1. If using the hardware trigger wait mode, setting the ADCS bit to 1 is prohibited (but the bit is
automatically switched to 1 when the hardware trigger signal is detected). However, it is possible
to clear the ADCS bit to 0 to specify the A/D conversion standby status.
2. While in the one-shot conversion mode of the hardware trigger no-wait mode, the ADCS flag is
not automatically cleared to 0 when A/D conversion ends. Instead, 1 is retained.
3 Only rewrite the value of the ADCE bit when ADCS = 0 (while in the conversion
stopped/conversion standby status).
4. To complete A/D conversion, specify at least the following time as the hardware trigger interval:
Hardware trigger no wait mode: 2 f
CLK clock + conversion start time + A/D conversion time
Hardware trigger wait mode: 2 f
CLK clock + conversion start time + A/D power supply
stabilization wait time + A/D conversion time