Datasheet
RL78/G14 3. ELECTRICAL SPECIFICATIONS (G: TA = -40 to +105 C)
R01DS0053EJ0200 Rev. 2.00 Page 167 of 187
Oct 25, 2013
3.6.7 Power supply voltage rising slope characteristics
Caution Make sure to keep the internal reset state by the LVD circuit or an external reset until VDD reaches the operating
voltage range shown in 3.4 AC Characteristics.
(2) LVD Detection Voltage of Interrupt & Reset Mode
(T
A = -40 to +105 C, VPDR VDD 5.5 V, VSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Interrupt and
reset mode
V
LVDD0 VPOC2, VPOC1, VPOC0 = 0, 1, 1, falling reset voltage 2.64 2.75 2.86 V
V
LVDD1 LVIS1, LVIS0 = 1, 0 Rising release reset voltage 2.81 2.92 3.03 V
Falling interrupt voltage 2.75 2.86 2.97 V
V
LVDD2 LVIS1, LVIS0 = 0, 1 Rising release reset voltage 2.90 3.02 3.14 V
Falling interrupt voltage 2.85 2.96 3.07 V
V
LVDD3 LVIS1, LVIS0 = 0, 0 Rising release reset voltage 3.90 4.06 4.22 V
Falling interrupt voltage 3.83 3.98 4.13 V
(TA = -40 to +105 C, VSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Power supply voltage rising slope S
VDD 54 V/ms