Datasheet
RL78/G14 3. ELECTRICAL SPECIFICATIONS (G: TA = -40 to +105 C)
R01DS0053EJ0200 Rev. 2.00 Page 132 of 187
Oct 25, 2013
(TA = -40 to +105 C, 2.4 V EVDD0 = EVDD1 VDD 5.5 V, VSS = EVSS0 = EVSS1 = 0 V) (2/2)
Items Symbol Conditions MIN. TYP. MAX. Unit
Timer RD input high-level
width, low-level width
t
TDIH,
t
TDIL
TRDIOA0, TRDIOA1, TRDIOB0, TRDIOB1,
TRDIOC0, TRDIOC1, TRDIOD0, TRDIOD1
3/fCLK ns
Timer RD forced cutoff signal
input low-level width
t
TDSIL P130/INTP0 2MHz < fCLK 32 MHz 1 s
f
CLK 2 MHz 1/fCLK + 1
Timer RG input high-level
width, low-level width
t
TGIH,
t
TGIL
TRGIOA, TRGIOB 2.5/fCLK ns
TO00 to TO03,
TO10 to TO13,
TRJIO0, TRJO0,
TRDIOA0, TRDIOA1,
TRDIOB0, TRDIOB1,
TRDIOC0, TRDIOC1,
TRDIOD0, TRDIOD1,
TRGIOA, TRGIOB
output frequency
f
TO HS (high-speed main) mode 4.0 V EVDD0 5.5 V 16 MHz
2.7 V
EVDD0 < 4.0 V 8 MHz
2.4 V
EVDD0 < 2.7 V 4 MHz
PCLBUZ0, PCLBUZ1 output
frequency
f
PCL HS (high-speed main) mode 4.0 V EVDD0 5.5 V 16 MHz
2.7 V
EVDD0 < 4.0 V 8 MHz
2.4 V
EVDD0 < 2.7 V 4 MHz
Interrupt input high-level
width, low-level width
t
INTH,
t
INTL
INTP0 2.4 V VDD 5.5 V 1 s
INTP1 to INTP11 2.4 V
EVDD0 5.5 V 1 s
Key interrupt input low-level
width
t
KR KR0 to KR7 2.4 V EVDD0 5.5 V 250 ns
RESET
low-level width
t
RSL
10 s