Datasheet

RL78/G12 3. ELECTRICAL SPECIFICATIONS (G: T
A = 40 to +105°C)
R01DS0193EJ0200 Rev.2.00
Sep 06, 2013
Page 100 of 106
3.6.4 LVD circuit characteristics
LVD Detection Voltage of Reset Mode and Interrupt Mode
(TA = 40 to +105°C, VPDR VDD 5.5 V, VSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Detection supply voltage VLVD0 Power supply rise time 3.90 4.06 4.22 V
Power supply fall time 3.83 3.98 4.13 V
VLVD1 Power supply rise time 3.60 3.75 3.90 V
Power supply fall time 3.53 3.67 3.81 V
VLVD2 Power supply rise time 3.01 3.13 3.25 V
Power supply fall time 2.94 3.06 3.18 V
VLVD3 Power supply rise time 2.90 3.02 3.14 V
Power supply fall time 2.85 2.96 3.07 V
VLVD4 Power supply rise time 2.81 2.92 3.03 V
Power supply fall time 2.75 2.86 2.97 V
VLVD5 Power supply rise time 2.70 2.81 2.92 V
Power supply fall time 2.64 2.75 2.86 V
VLVD6 Power supply rise time 2.61 2.71 2.81 V
Power supply fall time 2.55 2.65 2.75 V
VLVD7 Power supply rise time 2.51 2.61 2.71 V
Power supply fall time 2.45 2.55 2.65 V
Minimum pulse width tLW 300
μ
s
Detection delay time 300
μ
s