Datasheet
RL78/G13  2. ELECTRICAL SPECIFICATIONS (A, D: T
A = -40 to +85°C) 
Page 120 of 194R01DS0131EJ0310 Rev.3.10 
Nov 15, 2013 
LVD Detection Voltage of Interrupt & Reset Mode 
(T
A = −40 to +85°C, VPDR ≤ VDD ≤ 5.5 V, VSS = 0 V) 
Parameter Symbol  Conditions  MIN. TYP. MAX. Unit 
Interrupt and reset 
mode 
VLVDA0 VPOC2, VPOC1, VPOC0 = 0, 0, 0, falling reset voltage  1.60  1.63  1.66 
V 
VLVDA1    LVIS1, LVIS0 = 1, 0 Rising release reset voltage  1.74  1.77  1.81 
V 
Falling interrupt voltage  1.70  1.73  1.77 
V 
VLVDA2  LVIS1, LVIS0 = 0, 1 Rising release reset voltage  1.84  1.88  1.91 
V 
Falling interrupt voltage  1.80  1.84  1.87 
V 
VLVDA3  LVIS1, LVIS0 = 0, 0 Rising release reset voltage  2.86  2.92  2.97 
V 
Falling interrupt voltage  2.80  2.86  2.91 
V 
VLVDB0 VPOC2, VPOC1, VPOC0 = 0, 0, 1, falling reset voltage  1.80  1.84  1.87 
V 
VLVDB1    LVIS1, LVIS0 = 1, 0 Rising release reset voltage  1.94  1.98  2.02 
V 
Falling interrupt voltage  1.90  1.94  1.98 
V 
VLVDB2  LVIS1, LVIS0 = 0, 1 Rising release reset voltage  2.05  2.09  2.13 
V 
Falling interrupt voltage  2.00  2.04  2.08 
V 
VLVDB3  LVIS1, LVIS0 = 0, 0 Rising release reset voltage  3.07  3.13  3.19 
V 
Falling interrupt voltage  3.00  3.06  3.12 
V 
VLVDC0 VPOC2, VPOC1, VPOC0 = 0, 1, 0, falling reset voltage  2.40  2.45  2.50 
V 
VLVDC1    LVIS1, LVIS0 = 1, 0 Rising release reset voltage  2.56  2.61  2.66 
V 
Falling interrupt voltage  2.50  2.55  2.60 
V 
VLVDC2  LVIS1, LVIS0 = 0, 1 Rising release reset voltage  2.66  2.71  2.76 
V 
Falling interrupt voltage  2.60  2.65  2.70 
V 
VLVDC3  LVIS1, LVIS0 = 0, 0 Rising release reset voltage  3.68  3.75  3.82 
V 
Falling interrupt voltage  3.60  3.67  3.74 
V 
VLVDD0 VPOC2, VPOC1, VPOC0 = 0, 1, 1, falling reset voltage  2.70  2.75  2.81 
V 
VLVDD1    LVIS1, LVIS0 = 1, 0 Rising release reset voltage  2.86  2.92  2.97 
V 
Falling interrupt voltage  2.80  2.86  2.91 
V 
VLVDD2  LVIS1, LVIS0 = 0, 1 Rising release reset voltage  2.96  3.02  3.08 
V 
Falling interrupt voltage  2.90  2.96  3.02 
V 
VLVDD3  LVIS1, LVIS0 = 0, 0 Rising release reset voltage  3.98  4.06  4.14 
V 
Falling interrupt voltage  3.90  3.98  4.06 
V 
2.6.5 Power supply voltage rising slope characteristics 
(T
A = −40 to +85°C, VSS = 0 V) 
Parameter Symbol Conditions MIN. TYP. MAX. Unit 
Power supply voltage rising slope  SVDD      54  V/ms
Caution  Make sure to keep the internal reset state by the LVD circuit or an external reset until VDD 
reaches the operating voltage range shown in 2.4 AC Characteristics.  