Datasheet
RL78/G13  3. ELECTRICAL SPECIFICATIONS (G: T
A = -40 to +105°C) 
Page 140 of 194R01DS0131EJ0310 Rev.3.10 
Nov 15, 2013 
(3) Peripheral Functions (Common to all products) 
(TA = −40 to +105°C, 2.4 V ≤ EVDD0 = EVDD1 ≤ VDD ≤ 5.5 V, VSS = EVSS0 = EVSS1 = 0 V)   
Parameter Symbol  Conditions  MIN. TYP. MAX. Unit
Low-speed on-
chip oscillator 
operating 
current 
I
FIL
Note 1
 0.20  
μ
A 
RTC operating 
current 
IRTC
Notes 1, 2, 3
 0.02  
μ
A 
12-bit interval 
timer operating 
current 
I
IT
 Notes 1, 2, 
4
 0.02  
μ
A 
Watchdog timer 
operating 
current 
IWDT
Notes 1, 2, 5
f
IL = 15 kHz    0.22   
μ
A 
A/D converter 
operating 
current 
I
ADC
 Notes 
1, 6
When conversion 
at maximum 
speed 
Normal mode, AV
REFP = VDD = 5.0 V    1.3  1.7  mA 
Low voltage mode, AVREFP = VDD = 3.0 V    0.5  0.7  mA 
A/D converter 
reference 
voltage current 
I
ADREF
 Note 
1
 75.0  
μ
A 
Temperature 
sensor 
operating 
current 
I
TMPS
 Note 1
 75.0  
μ
A 
LVD operating 
current 
I
LVD
 Notes 1, 
7
 0.08  
μ
A 
Self 
programming 
operating 
current 
I
FSP
 Notes 1, 
9
 2.50 12.20 
mA 
BGO operating 
current 
I
BGO
 Notes 
1, 8
 2.50 12.20 
mA 
SNOOZE 
operating 
current 
I
SNOZ
 Note 1
ADC operation 
The mode is performed 
Note 10
 0.50 1.10 
mA 
The A/D conversion operations are 
performed, Loe voltage mode, AV
REFP = 
V
DD = 3.0 V 
 1.20 2.04 
mA 
CSI/UART operation    0.70  1.54 
mA 
Notes 1.  Current flowing to the VDD. 
 2.  When high speed on-chip oscillator and high-speed system clock are stopped. 
 3. Current flowing only to the real-time clock (RTC) (excluding the operating current of the low-speed on-
chip ocsillator and the XT1 oscillator). The supply current of the RL78 microcontrollers is the sum of the 
values of either I
DD1 or IDD2, and IRTC, when the real-time clock operates in operation mode or HALT mode.  
When the low-speed on-chip oscillator is selected, IFIL should be added. IDD2 subsystem clock operation 
includes the operational current of the real-time clock. 
 4.  Current flowing only to the 12-bit interval timer (excluding the operating current of the low-speed on-chip 
ocsillator and the XT1 oscillator). The supply current of the RL78 microcontrollers is the sum of the 
values of either I
DD1 or IDD2, and IIT, when the 12-bit interval timer operates in operation mode or HALT 
mode. When the low-speed on-chip oscillator is selected, I
FIL should be added.  
 5.  Current flowing only to the watchdog timer (including the operating current of the low-speed on-chip 
oscillator). The supply current of the RL78 is the sum of IDD1, IDD2 or IDD3 and IWDT when the watchdog 
timer operates. 