Datasheet
RL78/G13  2. ELECTRICAL SPECIFICATIONS (A, D: T
A = -40 to +85°C) 
Page 119 of 194R01DS0131EJ0310 Rev.3.10 
Nov 15, 2013 
2.6.4 LVD circuit characteristics 
LVD Detection Voltage of Reset Mode and Interrupt Mode 
 (T
A = −40 to +85°C, VPDR ≤ VDD ≤ 5.5 V, VSS = 0 V) 
Parameter Symbol  Conditions  MIN. TYP. MAX. Unit 
Detection 
voltage 
Supply voltage level  VLVD0 Power supply rise time  3.98 4.06 4.14 
V 
Power supply fall time  3.90  3.98  4.06 
V 
VLVD1 Power supply rise time  3.68 3.75 3.82 
V 
Power supply fall time  3.60  3.67  3.74 
V 
VLVD2 Power supply rise time  3.07 3.13 3.19 
V 
Power supply fall time  3.00  3.06  3.12 
V 
VLVD3 Power supply rise time  2.96 3.02 3.08 
V 
Power supply fall time  2.90  2.96  3.02 
V 
VLVD4 Power supply rise time  2.86 2.92 2.97 
V 
Power supply fall time  2.80  2.86  2.91 
V 
VLVD5 Power supply rise time  2.76 2.81 2.87 
V 
Power supply fall time  2.70  2.75  2.81 
V 
VLVD6 Power supply rise time  2.66 2.71 2.76 
V 
Power supply fall time  2.60  2.65  2.70 
V 
VLVD7 Power supply rise time  2.56 2.61 2.66 
V 
Power supply fall time  2.50  2.55  2.60 
V 
VLVD8 Power supply rise time  2.45 2.50 2.55 
V 
Power supply fall time  2.40  2.45  2.50 
V 
VLVD9 Power supply rise time  2.05 2.09 2.13 
V 
Power supply fall time  2.00  2.04  2.08 
V 
VLVD10 Power supply rise time  1.94 1.98 2.02 
V 
Power supply fall time  1.90  1.94  1.98 
V 
VLVD11 Power supply rise time  1.84 1.88 1.91 
V 
Power supply fall time  1.80  1.84  1.87 
V 
VLVD12 Power supply rise time  1.74 1.77 1.81 
V 
Power supply fall time  1.70  1.73  1.77 
V 
VLVD13 Power supply rise time  1.64 1.67 1.70 
V 
Power supply fall time  1.60  1.63  1.66 
V 
Minimum pulse width  tLW  300     
μ
s 
Detection delay time          300 
μ
s 










