Datasheet

RL78/G13 2. ELECTRICAL SPECIFICATIONS (A, D: T
A = -40 to +85°C)
Page 83 of 194R01DS0131EJ0310 Rev.3.10
Nov 15, 2013
(2) During communication at same potential (CSI mode) (master mode, SCKp... internal clock output,
corresponding CSI00 only)
(TA = 40 to +85°C, 2.7 V EVDD0 = EVDD1 VDD 5.5 V, VSS = EVSS0 = EVSS1 = 0 V)
Parameter Symbol Conditions HS (high-speed
main) Mode
LS (low-speed
main) Mode
LV (low-voltage
main) Mode
Unit
MIN. MAX. MIN. MAX. MIN. MAX.
SCKp cycle time tKCY1 tKCY1 2/fCLK 4.0 V EVDD0 5.5 V 62.5 250
500
ns
2.7 V EVDD0 5.5 V 83.3
250
500
ns
SCKp high-/low-level
width
tKH1,
t
KL1
4.0 V EV
DD0 5.5 V tKCY1/2
7
tKCY1/2
50
tKCY1/2
50
ns
2.7 V EVDD0 5.5 V tKCY1/2
10
tKCY1/2
50
tKCY1/2
50
ns
SIp setup time (to SCKp)
Note 1
t
SIK1 4.0 V EVDD0 5.5 V 23 110 110 ns
2.7 V EVDD0 5.5 V 33 110 110 ns
SIp hold time (from
SCKp)
Note 2
t
KSI1 2.7 V EVDD0 5.5 V 10 10 10 ns
Delay time from SCKp to
SOp output
Note 3
t
KSO1
C = 20 pF
Note 4
10 10 10 ns
Notes 1. When DAPmn = 0 and CKPmn = 0, or DAPmn = 1 and CKPmn = 1. The SIp setup time becomes “to
SCKp” when DAPmn = 0 and CKPmn = 1, or DAPmn = 1 and CKPmn = 0.
2. When DAPmn = 0 and CKPmn = 0, or DAPmn = 1 and CKPmn = 1. The SIp hold time becomes “from
SCKp” when DAPmn = 0 and CKPmn = 1, or DAPmn = 1 and CKPmn = 0.
3. When DAPmn = 0 and CKPmn = 0, or DAPmn = 1 and CKPmn = 1. The delay time to SOp output
becomes “from SCKp” when DAPmn = 0 and CKPmn = 1, or DAPmn = 1 and CKPmn = 0.
4. C is the load capacitance of the SCKp and SOp output lines.
Caution Select the normal input buffer for the SIp pin and the normal output mode for the SOp pin and
SCKp pin by using port input mode register g (PIMg) and port output mode register g (POMg).
Remarks 1. This value is valid only when CSI00’s peripheral I/O redirect function is not used.
2. p: CSI number (p = 00), m: Unit number (m = 0), n: Channel number (n = 0),
g: PIM and POM numbers (g = 1)
3. f
MCK: Serial array unit operation clock frequency
(Operation clock to be set by the CKSmn bit of serial mode register mn (SMRmn). m: Unit number,
n: Channel number (mn = 00))