Datasheet
RL78/G13 2. ELECTRICAL SPECIFICATIONS (A, D: T
A = -40 to +85°C)
Page 119 of 194R01DS0131EJ0310 Rev.3.10
Nov 15, 2013
2.6.4 LVD circuit characteristics
LVD Detection Voltage of Reset Mode and Interrupt Mode
(T
A = −40 to +85°C, VPDR ≤ VDD ≤ 5.5 V, VSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Detection
voltage
Supply voltage level VLVD0 Power supply rise time 3.98 4.06 4.14
V
Power supply fall time 3.90 3.98 4.06
V
VLVD1 Power supply rise time 3.68 3.75 3.82
V
Power supply fall time 3.60 3.67 3.74
V
VLVD2 Power supply rise time 3.07 3.13 3.19
V
Power supply fall time 3.00 3.06 3.12
V
VLVD3 Power supply rise time 2.96 3.02 3.08
V
Power supply fall time 2.90 2.96 3.02
V
VLVD4 Power supply rise time 2.86 2.92 2.97
V
Power supply fall time 2.80 2.86 2.91
V
VLVD5 Power supply rise time 2.76 2.81 2.87
V
Power supply fall time 2.70 2.75 2.81
V
VLVD6 Power supply rise time 2.66 2.71 2.76
V
Power supply fall time 2.60 2.65 2.70
V
VLVD7 Power supply rise time 2.56 2.61 2.66
V
Power supply fall time 2.50 2.55 2.60
V
VLVD8 Power supply rise time 2.45 2.50 2.55
V
Power supply fall time 2.40 2.45 2.50
V
VLVD9 Power supply rise time 2.05 2.09 2.13
V
Power supply fall time 2.00 2.04 2.08
V
VLVD10 Power supply rise time 1.94 1.98 2.02
V
Power supply fall time 1.90 1.94 1.98
V
VLVD11 Power supply rise time 1.84 1.88 1.91
V
Power supply fall time 1.80 1.84 1.87
V
VLVD12 Power supply rise time 1.74 1.77 1.81
V
Power supply fall time 1.70 1.73 1.77
V
VLVD13 Power supply rise time 1.64 1.67 1.70
V
Power supply fall time 1.60 1.63 1.66
V
Minimum pulse width tLW 300
μ
s
Detection delay time 300
μ
s