Datasheet
RL78/G13  2. ELECTRICAL SPECIFICATIONS (A, D: T
A = -40 to +85°C) 
Page 92 of 194R01DS0131EJ0310 Rev.3.10 
Nov 15, 2013 
(6)  Communication at different potential (1.8 V, 2.5 V, 3 V) (UART mode) (2/2) 
 (TA = −40 to +85°C, 1.8 V ≤ EVDD0 = EVDD1 ≤ VDD ≤ 5.5 V, VSS = EVSS0 = EVSS1 = 0 V) 
Parameter Symbol  Conditions  HS (high-
speed main) 
Mode 
LS (low-
speed main) 
Mode 
LV (low-
voltage 
main) Mode
Unit
MIN. MAX. MIN. MAX. MIN. MAX.
Transfer rate   
Transmission
 4.0 V ≤ EVDD0 ≤ 5.5 V,
2.7 V ≤ V
b ≤ 4.0 V 
Note 
1 
Note 
1 
Note 
1 
bps 
Theoretical 
value of the 
maximum 
transfer rate
C
b
 = 50 pF, R
b
 = 
1.4 k
Ω
, V
b
 = 2.7 
V
 2.8 
Note 2
 2.8  
Note 2
 2.8 
Note 2
Mbps
2.7 V ≤ EVDD0 < 4.0 V,
2.3 V ≤ V
b ≤ 2.7 V 
Note 
3 
Note 
3 
Note 
3 
bps 
Theoretical 
value of the 
maximum 
transfer rate
C
b
 = 50 pF, R
b
 = 
2.7 k
Ω
, V
b
 = 2.3 
V
 1.2 
Note 4
 1.2  
Note 4
 1.2 
Note 4
Mbps
1.8 V ≤ EVDD0 < 3.3 V,
1.6 V ≤ V
b ≤ 2.0 V 
Notes 
5, 6
Notes 
5, 6 
Notes 
5, 6 
bps 
Theoretical 
value of the 
maximum 
transfer rate
C
b
 = 50 pF, R
b
 = 
5.5 k
Ω
, V
b
 = 1.6 
V
 0.43 
Note 7
 0.43  
Note 7
 0.43 
Note 7
Mbps
Notes  1.  The smaller maximum transfer rate derived by using f
MCK/6 or the following expression is the valid 
maximum transfer rate. 
Expression for calculating the transfer rate when 4.0 V ≤ EV
DD0 ≤ 5.5 V and 2.7 V ≤ Vb ≤ 4.0 V 
Maximum transfer rate = 
1 
 [bps] 
{−C
b × Rb × ln (1 − 
 2.2 
V
b
)} × 3
 1 
 Transfer rate × 2 
 − {−Cb × Rb × ln (1 − 
 2.2 
V
b
)} 
Baud rate error (theoretical value) =
 × 100 [%] 
(
 1 
 Transfer rate 
) × Number of transferred bits 
* This value is the theoretical value of the relative difference between the transmission and reception sides. 
 2.  This value as an example is calculated when the conditions described in the “Conditions” column are 
met. Refer to Note 1 above to calculate the maximum transfer rate under conditions of the customer. 