Datasheet

Section 2 CPU
R01UH0309EJ0500 Rev. 5.00 Page 57 of 1408
Sep 24, 2012
H8S/2456, H8S/2456R, H8S/2454 Group
2.4.4 Condition-Code Register (CCR)
This 8-bit register contains internal CPU status information, including an interrupt mask bit (I) and
half-carry (H), negative (N), zero (Z), overflow (V), and carry (C) flags.
Operations can be performed on the CCR bits by the LDC, STC, ANDC, ORC, and XORC
instructions. The N, Z, V, and C flags are used as branching conditions for conditional branch
(Bcc) instructions.
Bit Bit Name Initial Value R/W Description
7 I 1 R/W Interrupt Mask Bit
Masks interrupts other than NMI when set to 1.
NMI is accepted regardless of the I bit setting.
The I bit is set to 1 by hardware at the start of an
exception-handling sequence. For details, see
section 5, Interrupt Controller.
6 UI Undefined R/W User Bit or Interrupt Mask Bit
Can be written and read by software using the
LDC, STC, ANDC, ORC, and XORC
instructions. This bit cannot be used as an
interrupt mask bit in this LSI.
5 H Undefined R/W Half-Carry Flag
When the ADD.B, ADDX.B, SUB.B, SUBX.B,
CMP.B, or NEG.B instruction is executed, this
flag is set to 1 if there is a carry or borrow at bit
3, and cleared to 0 otherwise. When the ADD.W,
SUB.W, CMP.W, or NEG.W instruction is
executed, the H flag is set to 1 if there is a carry
or borrow at bit 11, and cleared to 0 otherwise.
When the ADD.L, SUB.L, CMP.L, or NEG.L
instruction is executed, the H flag is set to 1 if
there is a carry or borrow at bit 27, and cleared
to 0 otherwise.
4 U Undefined R/W User Bit
Can be written and read by software using the
LDC, STC, ANDC, ORC, and XORC
instructions.
3 N Undefined R/W Negative Flag
Stores the value of the most significant bit of
data as a sign bit.