Datasheet
Section 11 16-Bit Timer Pulse Unit (TPU)
R01UH0309EJ0500 Rev. 5.00 Page 739 of 1408
Sep 24, 2012
H8S/2456, H8S/2456R, H8S/2454 Group
11.3.10 Timer Start Register B (TSTRB)
TSTRB selects operation/stoppage for channels 6 to 11. When setting the operating mode in
TMDR or setting the count clock in TCR, first stop the TCNT counter.
Bit Bit Name Initial value R/W Description
7
6
⎯
⎯
0
0
⎯
⎯
Reserved
The write value should always be 0.
5
4
3
2
1
0
CST11
CST10
CST9
CST8
CST7
CST6
0
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
Counter Start 11 to 6
These bits select operation or stoppage for TCNT.
If 0 is written to the CST bit during operation with the
TIOC pin designated for output, the counter stops
but the TIOC pin output compare output level is
retained. If TIOR is written to when the CST bit is
cleared to 0, the pin output level will be changed to
the set initial output value.
0: TCNT_11 to TCNT_6 count operation is stopped
1: TCNT_11 to TCNT_6 performs count operation