Datasheet

Section 20 Synchronous Serial Communication Unit (SSU)
Page 1138 of 1408 R01UH0309EJ0500 Rev. 5.00
Sep 24, 2012
H8S/2456, H8S/2456R, H8S/2454 Group
Yes
[1]
[2]
[3]
[4]
[1] Initial setting:
Specify the receive data format.
[2], [4] Receive error processing:
When a receive error occurs, execute the designated error
processing after reading the ORER bit in SSSR. After that,
clear the ORER bit to 0. While the ORER bit is set to 1,
transmission or reception is not resumed.
[3] To complete reception:
To complete reception, read receive data after clearing the
RE bit to 0. When reading SSRDR without clearing the RE
bit, reception is resumed.
No
Yes
Yes
No
Start
Initial setting
Read SSSR
RDRF = 1?
ORER = 1?
Consecutive data reception?
Read received data in SSRDR
RDRF automatically cleared
RE = 0
Read receive data in SSRDR
End reception
Overrun error processing
Clear ORER in SSSR
End reception
Note: Hatching boxes represent SSU internal operations.
No
Figure 20.16 Flowchart Example of Data Reception
(Clock Synchronous Communication Mode)