Datasheet

Section 15 Serial Communication Interface (SCI, IrDA)
R01UH0310EJ0500 Rev. 5.00 Page 885 of 1384
Sep 25, 2012
H8S/2426, H8S/2426R, H8S/2424 Group
Bit Bit Name Initial Value R/W Description
5 ORER 0 R/(W)
*
Overrun Error
Indicates that an overrun error occurred while
receiving and the reception has ended abnormally.
[Setting condition]
When the next serial reception is completed
while RDRF = 1
The receive data prior to the overrun error is
retained in RDR, and the data received
subsequently is lost. Also, subsequent serial
reception cannot be continued while the ORER
flag is set to 1. In clocked synchronous mode,
serial transmission cannot be continued,
either.
[Clearing condition]
When 0 is written to ORER after reading
ORER = 1
The ORER flag is not affected and retains its
previous state when the RE bit in SCR is
cleared to 0.
4 ERS 0 R/(W)
*
Error Signal Status
[Setting condition]
When the low level of the error signal is
sampled
[Clearing conditions]
When 0 is written to ERS after reading
ERS = 1