Datasheet
Section 15 Serial Communication Interface (SCI, IrDA) 
R01UH0310EJ0500 Rev. 5.00    Page 881 of 1384 
Sep 25, 2012     
H8S/2426, H8S/2426R, H8S/2424 Group 
Bit  Bit Name  Initial Value  R/W  Description 
5 ORER  0  R/(W)
*
 Overrun Error 
Indicates that an overrun error occurred while 
receiving and the reception has ended abnormally.
[Setting condition] 
•  When the next serial reception is completed 
while RDRF = 1 
The receive data prior to the overrun error is 
retained in RDR, and the data received 
subsequently is lost. Also, subsequent serial 
reception cannot be continued while the ORER 
flag is set to 1. In clocked synchronous mode, 
serial transmission cannot be continued, 
either. 
[Clearing condition] 
•  When 0 is written to ORER after reading 
ORER = 1 
The ORER flag is not affected and retains its 
previous state when the RE bit in SCR is 
cleared to 0. 